Cables for MV Power Distribution - Earthed versus Unearthed Systems

By Jeson Pitt on 8/12/2013 12:37 PM

Power cables can basically be classified into earthed and unearthed cables, where earthed and unearthed refer to the application for which the cable is used. Earthed system refers to a three phase syste... read more..


Photovoltaic (PV) - Utility Power Grid Interface

By Steven McFadyen on 4/4/2013 12:47 PM

Photovoltaic (PV) systems are typically more efficient when connected in parallel with a main power gird. During periods when the PV system generates energy this can be utilized and the grid energy u... read more..


Switchboard - Forms of Internal Separation

By Steven McFadyen on 1/29/2012 12:57 PM

IEC 61439 'Low-voltage switchgear and controlgear assemblies', specifies standard arrangements of switchboard (call forms of internal separation).

read more..


Fire Resistant and Fire Retardant Cables

By Steven McFadyen on 7/4/2013 1:31 PM

Fire resistant and fire retardant cable sheaths are design to resist combustion and limit the propagation of flames. Low smokes cables have a sheath designed to limit the amount of smoke and toxic ha... read more..


How to measure power supply quality

By Steven McFadyen on 2/14/2012 11:43 AM

If your are ever called out to troubleshoot something on your electrical system, one of the first things consider is the supply voltage. You want to ensure you have a good electrical supply before movin... read more..


IEC Document Designation

By Steven McFadyen on 5/9/2012 2:07 PM

Often document control is dictated by project requirements, for example a particular organisation may have an existing numbering system. Existing company or group/department document control systems may... read more..


Lighting Design - An Introduction

By Steven McFadyen on 4/12/2012 1:50 PM

From the earliest times, humans have found ways to create light. Pre-historic peoples used natural materials (moss, grass, etc.) soaked in animal fat and then ignited. Around 3000 to 4500 BC, oil lam... read more..


Low Voltage Circuit Breakers

By Steven McFadyen on 4/15/2012 1:55 PM

Circuit breakers are switching devices whose primary function is to isolate parts of an electrical distribution system in the even of abnormal conditions.  Abnormal conditions are generally caused ... read more..


Medium Voltage Switchgear Room Design Guide

By Steven McFadyen on 5/9/2012 2:12 PM

Many medium voltage (MV) indoor switchgear rooms  exist worldwide. The complexity of these rooms varies considerably depending on location, function and technology adopted by the owner. This articl... read more..


Low Voltage Switchroom Design Guide

By Steven McFadyen on 5/9/2012 2:10 PM

Low voltage (LV) switchrooms are common across all industries and one of the more common spatial requirements which need to be designed into a project. Main LV switchrooms w... read more..


Standard Cable & Wire Sizes

By Steven McFadyen on 4/9/2012 7:45 AM

IEC 60228 is the International Electrotechnical Commission's international standard on conductors of insulated cables. Among other things, it defines a set of standard wire cross-sections. In the United... read more..


Power Factor

By Steven McFadyen on 7/10/2012 11:43 AM

Power factor is the ratio between the real power (P in kW) and apparent power (S in kVA) drawn by an electrical load.

The reactive power (Q in kVAr) causes the real and apparent power to be ... read more..




Why a Sine Wave?

I received this question by email a few weeks. First thoughts was that it is a product of the mathematics of rotating a straight conductor in a magnetic...

Fault Calculation - Symmetrical Components

For unbalance conditions the calculation of fault currents is more complex. One method of dealing with this is symmetrical components. Using symmetrical...

IEC 60287 Current Capacity of Cables - Rated Current

In the previous note we looked at the approach taken by the standard to the sizing of cables and illustrated this with an example.  We then looked at one...

What is a rectifier transformer?

I've recently come across this question a couple times browsing the internet. Decided to give a quick answer here. A rectifier transformer is a transformer...

Arc Flash Calculations

Working in the vicinity of electrical equipment poses an hazard. In addition to electric shock hazard, fault currents passing through air causes Arc Flash...

A mechanical engineering paper, some history and memories

I was digging in my bookshelf and came across the 80th Anniversary Association of Mine Resident Engineers, Papers and Discussions Commemorative Edition...

Photovoltaic (PV) - Utility Power Grid Interface

Photovoltaic (PV) systems are typically more efficient when connected in parallel with a main power gird. During periods when the PV system generates energy...

Understanding Circuit Breaker Markings

IEC 60947 is the circuit breaker standard and covers the marking of breakers in detail. Any manufacturer following this standard should comply with the...

Meeting room of the future

The IET site has a video of a visit showing of a high tech meeting room developed at Napier University in Edinburgh. It a good demonstration of innovative...

Understanding LV Circuit Breaker Fault Ratings

I think this post is going to be helpful to several of our readers. While the IEC low voltage circuit breaker Standard [IEC 60947-2, Low voltage switchgear...

Have some knowledge to share

If you have some expert knowledge or experience, why not consider sharing this with our community.  

By writing an electrical note, you will be educating our users and at the same time promoting your expertise within the engineering community.

To get started and understand our policy, you can read our How to Write an Electrical Note